		<title>How can I see the changes or events that have occurred for a specific WinSPC item?</title>
		<link>https://knowledgebase.winspc.com/questions/115/</link>
		<description>WinSPC can be configured to track and record changes to objects in WinSPC, such as when items are created, modified, or deleted.  This information is stored in the WinSPC Event Log (also called th ...</description>
		<author>Keith Bates</author>
		<pubDate>Wed, 01 Jul 2020 18:14:09 GMT</pubDate>
	</item>
	<item>
		<title>How do I setup and use an OPC device?</title>
		<link>https://knowledgebase.winspc.com/questions/205/</link>
		<description>OPC stands for Open Process Control (previously stood for Object Linking and Embedding for Production Control, but the OLE technology has been replaced by Active X).  An OPC server is a software i ...</description>
		<author>Dale Mothorpe</author>
		<pubDate>Wed, 01 Jul 2020 17:58:45 GMT</pubDate>
	</item>
	<item>
		<title>How do I setup WinSPC to get data on a timed basis?</title>
		<link>https://knowledgebase.winspc.com/questions/35/</link>
		<description>WinSPC has the ability to prompt a device to send a reading, or prompt the operator that a reading is required, at certain intervals or at specific times during Data Collection.  This can free up  ...</description>
		<author>Dale Mothorpe</author>
		<pubDate>Tue, 20 Aug 2019 16:18:14 GMT</pubDate>
	</item>
	<item>
		<title>Matching External Data Source Readings with Collection Plan Steps</title>
		<link>https://knowledgebase.winspc.com/questions/329/</link>
		<description>Readings from an external data source must, in the end, be matched with the appropriate step in a collection plan. When the data source feeds only one step, this is assured.When the data source fe ...</description>
		<author>Daniel Jacobovitz</author>
		<pubDate>Thu, 14 Feb 2019 18:01:30 GMT</pubDate>
	</item>
	<item>
		<title>How do I setup a Microsoft Excel file device?</title>
		<link>https://knowledgebase.winspc.com/questions/284/</link>
		<description>Data stored in simple Excel files (.xls or .xlsx files) can be used to automatically populate variables and tags in WinSPC using an &amp;lsquo;Excel file&amp;rsquo; device. As the Excel file gets updated  ...</description>
		<author>Dale Mothorpe</author>
		<pubDate>Fri, 28 Dec 2018 18:43:56 GMT</pubDate>
	</item>
	<item>
		<title>How do I setup an ODBC device to pull from multiple fields in my database?</title>
		<link>https://knowledgebase.winspc.com/questions/45/</link>
		<description>In WinSPC 8.0 or later, you can use a single ODBC (database) device to collect data from multiple fields in your database and store those values into separate variables.  The configuration of the  ...</description>
		<author>Keith Bates</author>
		<pubDate>Tue, 06 Nov 2018 16:59:15 GMT</pubDate>
	</item>
	<item>
		<title>How do I create a Device in WinSPC?</title>
		<link>https://knowledgebase.winspc.com/questions/298/</link>
		<description>WinSPC can collect values--data or tag values--from devices. Devices here means not only serial devices but text files, DDE servers, OLE Automation servers, OPC servers, ODBC servers and Microsoft ...</description>
		<author>Dale Mothorpe</author>
		<pubDate>Thu, 06 Sep 2018 19:33:11 GMT</pubDate>
	</item>
	<item>
		<title>How can I control the numeric format (regional settings) used when a device interprets data?</title>
		<link>https://knowledgebase.winspc.com/questions/310/</link>
		<description>When a serial (RS232) device, networked device, or text file device processes data values, it has to know what a numeric reading looks like.  In some areas of the world, the decimal separator of a ...</description>
		<author>Keith Bates</author>
		<pubDate>Fri, 27 Jul 2018 15:11:33 GMT</pubDate>
	</item>
	<item>
		<title>How does a WinSPC Excel Device deal with blank cells?</title>
		<link>https://knowledgebase.winspc.com/questions/153/</link>
		<description>The Excel device, which, in WinSPC 9.0 and above, can open XLS, XLSX and CSV files, handles blank (empty) cells in the Excel worksheet depending on the features enabled in the device setup for the ...</description>
		<author>Keith Bates</author>
		<pubDate>Fri, 27 Jul 2018 13:58:31 GMT</pubDate>
	</item>
	<item>
		<title>How do I setup and use a DDE Server device?</title>
		<link>https://knowledgebase.winspc.com/questions/15/</link>
		<description>WinSPC has the ability to gather data from a Dynamic Data Exchange (DDE) server device. Setting up a DDE server device involves selecting the DDE server device type and then setting up the device&#039; ...</description>
		<author>Dale Mothorpe</author>
		<pubDate>Tue, 20 Mar 2018 20:58:39 GMT</pubDate>
	</item>
	<item>
		<title>How do I setup and use an OLE Automation Server device?</title>
		<link>https://knowledgebase.winspc.com/questions/304/</link>
		<description>WinSPC has the ability to gather data from an Object Linking &amp;amp; Embedding OLE Automation Server device. Setting up an OLE Automation Server device involves selecting the OLE Automation Server d ...</description>
		<author>Dale Mothorpe</author>
		<pubDate>Tue, 20 Mar 2018 20:57:56 GMT</pubDate>
	</item>
	<item>
		<title>How does a bar-code scanner work with WinSPC?</title>
		<link>https://knowledgebase.winspc.com/questions/18/</link>
		<description>A common method of input for tag values and data samples within WinSPC is by using a barcode or QC reader. A barcode reader usually behaves in one of 2 basic ways: 

Acts as a keyboard wedge
Se ...</description>
		<author>Daniel Jacobovitz</author>
		<pubDate>Wed, 29 Nov 2017 23:36:34 GMT</pubDate>
	</item>
	<item>
		<title>How do I setup and use a Text File device?</title>
		<link>https://knowledgebase.winspc.com/questions/204/</link>
		<description>WinSPC has the ability to parse and read data into variables from various text files layouts (including comma separate variable (CSV)).  Using the masking capabilities from within Device setup you ...</description>
		<author>Dale Mothorpe</author>
		<pubDate>Thu, 11 May 2017 15:04:17 GMT</pubDate>
	</item>
	<item>
		<title>What is the difference between a promptable and non-promptable device in WinSPC?</title>
		<link>https://knowledgebase.winspc.com/questions/19/</link>
		<description>Introduction
A device in WinSPC is used to collect data from external sources (such as a serial gauge, text file, database, etc). These devices can function in one of two modes: Promptable or Non ...</description>
		<author>Keith Bates</author>
		<pubDate>Tue, 25 Mar 2014 14:28:50 GMT</pubDate>
	</item>
	<item>
		<title>Can WinSPC automatically prompt a device for data on a timed basis?</title>
		<link>https://knowledgebase.winspc.com/questions/164/</link>
		<description>IntroductionIs it possible to automate data collection by having WinSPC be set to prompt a device.Procedure

Set up the Device as you normally would. 
Set up a Collection Plan step to use the d ...</description>
		<author>Keith Bates</author>
		<pubDate>Wed, 19 Feb 2014 17:46:44 GMT</pubDate>
	</item>
	<item>
		<title>How do I setup and use a serial device?</title>
		<link>https://knowledgebase.winspc.com/questions/16/</link>
		<description>     WinSPC has the ability to gather data from most serial devices.  A serial device is serial communication through a physical interface, usually a serial port, which information is transferred  ...</description>
		<author>Dale Mothorpe</author>
		<pubDate>Fri, 21 Jun 2013 17:24:04 GMT</pubDate>
	</item>
	<item>
		<title>How do I create a 32-bit ODBC DSN on a 64-bit operating system?</title>
		<link>https://knowledgebase.winspc.com/questions/307/</link>
		<description>When using Custom Web Reporter (CWR), QualTrend, or WinSPC&#039;s ODBC device, you may need to create an ODBC DSN on a computer in order to tell the application how to connect to an external database.  ...</description>
		<author>Keith Bates</author>
		<pubDate>Thu, 30 Aug 2012 11:24:21 GMT</pubDate>
	</item>