How do I reset or change a WinSPC user's password? [Article]
To reset or change a WinSPC user's password:
Log into WinSPC as an administrator user that has permissions to edit the user.
In the "Users" tree of the WinSPC adm
How do I add a cover page to my report template? [Article]
To add a cover page to an existing report template:
Make a copy of your existing report template (just so you have a backup of the original).
Edit the properties of the
How do I upgrade WinSPC? [Article]
To upgrade your WinSPC system, you should refer to the "Upgrade Instructions" that comes with your WinSPC installation media (download or CD). These instructions will take you step by step
Using the WinSPC API with Station Aliasing [Article]
Note: This article only applies to WinSPC 8.2.0 or later. Station aliasing is a feature that was introduced in WinSPC 8.2 and allows a WinSPC client to use a different station
How do I setup or modify a User? [Article]
...s accounts with unique permissions, settings and preferences. User accounts control which areas of WinSPC th
How can I customize a trigger e-mail notification? [Article]
Not only can you have an e-mail automatically sent to whomever you want when a trigger fires, you can customize the content of the e-mail so that it contains all the relevant information.
Capability Report (Legacy) [Article]
Current Report Version: 1.0.1 The capability report displays a variety of information about a specific variable on a single page, including statistics such as mean, standard deviation, Cpk,
Capability Report [Article]
Current Report Version: 1.0.1 The capability report displays a variety of information about a specific variable on a single page, including statistics such as mean, standard deviation, Cpk,
How are control limits calculated for an attribute c-chart? [Article]
A c-chart displays the total number of nonconformities for each lot. This chart is available in WinSPC to an attribute that is configured with an 'Attribute Counts' of 'Defect
How are control limits calculated for an attribute u-chart? [Article]
A u-chart displays the number of nonconformities per unit produced. This chart is available in WinSPC to an attribute that is configured with an 'Attribute Counts' of 'Defects
How are control limits calculated for an attribute np-chart? [Article]
An np-chart displays the number of nonconforming (defective) units. This chart is available in WinSPC to an attribute that is configured with an 'Attribute Counts' of 'Defecti
How are control limits calculated for an attribute p-chart? [Article]
A p-chart displays the percentage of nonconforming (defective) units. This chart is available in WinSPC to an attribute that is configured with an 'Attribute Counts' of 'Defec